Polystyrene EPS 100-038 Roof - floor
APPLICATION
according to PN-B-20132 “Heat insulation building products. Polystyrene panels (EPS). Application Principles”:
- heat insulation of plinths in Seamless Heat Insulation Systems
- heat insulation of walls below ground level, with insulation against water, normal loading
- heat insulation of floors below ground beam with prefabricated panels
- heat insulation of floors below ground beam, normal loading
- heat insulation of floors at ground level with flooring ground beam, normal loading
- heat insulation of full roof floors without access
PHYSICAL PARAMETERS
| Trait |
Class/Level |
Tolerance/Requirements |
| Thickness | T1 |
± 2 mm |
| Length |
L1 |
± 0,6% lub ± 3mma |
| Width |
W1 |
± 0,6% lub ± 3mma |
| Rectangularity |
S1 |
± 5 mm/1000 mm |
| Flatness |
P3 |
± 10 mm |
| Resistance to bending | BS150 |
≥ 150 kPa |
| Compression stress at 10% distortion |
CS(10)100 |
≥ 100 kPa |
| Dimensional stability in fixed normal laboratory conditions |
DS(N)2 |
± 0,5 % |
| Dimensional stability in defined temperature and humidity conditions |
DS(70,-)2 |
≤ 2 % |
| Distortion in defined compression loading and temperature conditions |
DLT(1)5 |
≤ 5 % |
| Declared heat conductivity coefficient λd |
- |
≤ 0,038 W/(m-K) |
| Fire reaction class | E | - |
| a This is the value which gives numerically greater tolerance |
||