APPLICATION

 

  • heat insulation of cavity walls with ventilated air cavity and elements of cladding
  • heat insulation of walls in Seamless Heat Insulation Systems
  • heat insulation of roof constructions executed as shuttering lost under plaster 
  • heat insulation of lintels and door and window frames 
  • heat insulation of floors from underneath in Seamless
  • Heat Insulation Systems 
  • heat insulation and planking lost in steel reinforced concrete floors 


PHYSICAL PARAMETERS

Trait
Class/Level
 Tolerance/Requirements
Thickness
T2
± 1 mm
Length
L2
± 2 mm
Width
W2
± 2 mm
Rectangularity
S2
± 2 mm/1000 mm
Flatness
P3
± 10 mm
Resistance to bending
BS100
≥ 100 kPa
Dimensional stability in fixed normal laboratory conditions
DS(N)2
± 0,2 %
Dimensional stability in defined temperature and humidity conditions
DS(70,-)2
≤ 2 %
Resistance to stretching
TR100
≥ 100 kPa
Declared heat conductivity coefficient λd
-
≤ 0,040 W/(m-K)
Fire reaction class E
-